PO - Pilot O perated Check Valves PO - 2 Pilot Operated Check Valves Catalog 11141715 • Rev CB • March 2016 * Flow ratings are based on a pressure drop of 7 bar [100 psi] unless otherwise noted. They are for comparison purposes only. Quick Reference Q uick Reference Pilot to Open Model No. Cavity Description Flow* Pressure Page RPC04 NCS04/3 Pilot Operated Check Valve, Pilot to Open 20.5 l/min [5.4 US gal/min] 350 bar [5075 psi] PO - 7 RPC06 NCS06/3 35 l/min [9.3 US gal/min] 350 bar [5075 psi] PO - 8 CP450-1 SDC10-3 30 l/min [8 US gal/min] 240 bar [3480 psi] PO - 9 RPC12 NCS12/3 90 l/min [23.8…
File type: application/pdf
Referenced at:
PO - Pilot O perated Check Valves PO - 2 Pilot Operated Check Valves Catalog 11141715 • Rev CB • March 2016 * Flow ratings are based on a pressure drop of 7 bar [100 psi] unless otherwise noted. They are for comparison purposes only. Quick Reference Q uick Reference Pilot to Open Model No. Cavity Description Flow* Pressure Page RPC04 NCS04/3 Pilot Operated Check Valve, Pilot to Open 20.5 l/min [5.4 US gal/min] 350 bar [5075 psi] PO - 7 RPC06 NCS06/3 35 l/min [9.3 US gal/min] 350 bar [5075 psi] PO - 8 CP450-1 SDC10-3 30 l/min [8 US gal/min] 240 bar [3480 psi] PO - 9 RPC12 NCS12/3 90 l/min [23.8…
File type: application/pdf
Referenced at:
HC3- D miniBOOSTER Description The HC3 - D is a variant of the HC3, with all ports in one end. The entire pattern is a miniBOOSTER design. It is a compact unit weighing only 1.75 kg. The HC3 - D has the pilot- operated dump valve incorporated as a standard feature. Maximum outlet pressure is 800 bar in standard versions. An adjustment of the outlet pressure is carried out by varying the supplied pressure. Flow rates Intensification factor i Max. outlet flow l/ min Max. inlet flow l/ min 1.2 1.2 8.0 1.5 1.0 8.0 2.0 2.0 12.0 2.8 2.2 13.0 3.2 2.5 15.0 4.0 2.0 14.0 5.0 1.6 14.0 6.6 1.3 13.0 9.0…
File type: application/pdf
Referenced at:
Series 42 Axial Piston Pumps Technical Information 2 11022637 • Rev. CD • June 2010 Series 42 Axial Piston Pumps Technical Information Revisions © 2010 Sauer-Danfoss. All rights reserved. Sauer-Danfoss accepts no responsibility for possible errors in catalogs, brochures and other printed material. Sauer-Danfoss reserves the right to alter its products without prior notice. This also applies to products already ordered provided that such alterations aren’t in conflict with agreed specifications. All trademarks in this material are properties of their respective owners. Sauer-Danfoss and the…
File type: application/pdf
Referenced at:
miniBOOSTER HC3- I Beschreibung Der HC3 - I ist eine Variante des HC3, die Hochdruck am Anschluss B liefert und. für die Verwendung in NG6 (D03) Steuerblöcken ausgelegt ist. Das kompakte Gerät wiegt nur 3,5 kg. Der HC3 verfügt serienmäßig über ein gesteuertes Rücklaufventil. In der Standardversion liegt der maximale Ausgangsdruck bei 500 bar. Die Einstellung des Ausgangsdrucks erfolgt über die Regelung des Eingangsdrucks. Durchflussmenge Verstärkungsfaktor i Max. Ausgang l/ min Max. Eingang l/ min 1,2 1,2 8,0 1,5 1,0 8,0 2,0 2,0 12,0 2,8 2,2 13,0 3,2 2,5 15,0 4,0 2,0 14,0 5,0 1,6 14,0 6,6 1,3…
File type: application/pdf
Referenced at:
HC3- F miniBOOSTER Description The HC3 - F is an up- right standing variant of the HC3 with a 10 micron filter and 2 orifices incorporated. It has all ports in one end and the entire pattern is a miniBOOSTER design. It is a compact unit weighing only 4.3 kg. The HC3 has the pilot- operated dump valve incorporated as a standard feature. Maximum outlet pressure is 500 bar in standard versions. Adjustments of the outlet pressure is carried out by varying the supplied pressure. Flow Rates Intensification factor i Max. outlet flow l/ min Max. inlet flow l/ min 1.2 1.2 8.0 1.5 1.0 8.0 2.0 2.0 12.0…
File type: application/pdf
Referenced at:
HC3 miniBOOSTER Description The HC3 is a version of the HC2 designed for use in NG6 (D03) stacking manifold systems. It is a compact unit weighing only 2.5 kg. The HC3 has the pilot- operated dump valve incorporated as a standard feature. Maximum outlet pressure is 500 bar in standard versions. Adjustments of the outlet pressure is carried out by varying the supplied pressure. Flow rates Intensification factor i Max. outlet flow l/ min Max. inlet flow l/ min 1.2 1.2 8.0 1.5 1.0 8.0 2.0 2.0 12.0 2.8 2.2 13.0 3.2 2.5 15.0 4.0 2.0 14.0 5.0 1.6 14.0 6.6 1.3 13.0 9.0 0.9 13.0 13.0 0.6 12.0 20.0 0.3…
File type: application/pdf
Referenced at:
T E C H N I C A L C A T A L O G MW14 HYDRAULIC MOTORS Modular hydraulic motors MW14 POCLAIN HYDRAULICS 2 24/02/2011 CHARACTERISTICS For other cams: Please contact your Poclain Hydraulics application engineer. Contact your Poclain Hydraulics application engineer to find out how the displacement shift from the third to the second displacement is controlled and to find out trans- mission capabilities in terms of displacement shift when the vehicle is in motion. 1 401 934 467 [85,4] [57,0] [28,5] 2 230 1 486 743 [1 133] [755] [378] 50 40 33 [67] [54] [44] 2 [6 530] 450 120 145 175 Displacement…
File type: application/pdf
Referenced at:
OMEW Standard and with Low Speed Option Orbital Motors Technical Information 2 520L0570 • Rev BB • Mar 2010 © 2010 Sauer-Danfoss. All rights reserved. Sauer-Danfoss accepts no responsibility for possible errors in catalogs, brochures and other printed material. Sauer -Danfoss reserves the right to alter its products without prior notice. This also applies to products already ordered provided that such alterations can be made without affecting agreed specifications. All trademarks in this material are properties of their respective owners. Sauer-Danfoss, the Sauer-Danfoss logotype, the…
File type: application/pdf
Referenced at:
11055368 • Rev EA • Oct 2013 Features y Designed for quality and reliability – One design concept – Single piece swash plate y Installation and packaging benefits – Length optimized pump – Minimum one clean side – Higher corner power – Higher package size ratio – Standardized connector interface – Expanded functionality through PLUS+1® y Optimized for electrical control – Electro-hydraulic control options include Electrical Displacement Control (EDC), Forward-Neutral-Reverse (FNR) and Non-Feedback Proportional Electric (NFPE) – Automotive Control (AC) – Fan Drive Control (FDC) – Common control…
File type: application/pdf