Group 2 Gear Pumps Technical Information OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP ™ 2 OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP ™ L1016341 • June 2010 • Rev A Group 2 Gear Pumps Technical Information Table of revisions Date Page Changed Rev. 28, June 2010 - First edition A Literature reference for gear products Title Type Order number General Aluminum Gear Pumps and Motors Technical Information L1016238 Group 1 Gear Pumps Technical Information L1016399 Group 3 Gear Pumps Technical Information L1016456 Group 1, 2 and 3 Gear Motors Technical Information L1016082 Hydraulic Fluids…
Dateityp: application/pdf
Verlinkt bei:
Group 2 Gear Pumps Technical Information OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP ™ 2 OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP ™ L1016341 • June 2010 • Rev A Group 2 Gear Pumps Technical Information Table of revisions Date Page Changed Rev. 28, June 2010 - First edition A Literature reference for gear products Title Type Order number General Aluminum Gear Pumps and Motors Technical Information L1016238 Group 1 Gear Pumps Technical Information L1016399 Group 3 Gear Pumps Technical Information L1016456 Group 1, 2 and 3 Gear Motors Technical Information L1016082 Hydraulic Fluids…
Dateityp: application/pdf
Verlinkt bei:
miniBOOSTER HC7 Beschreibung Der HC7 ist ein sehr kompaktes Hochdruckgerät, das bei einem Gewicht von nur 1,5 kg Drücke bis zu 2.000 bar liefern kann. Zudem eignet er sich ideal für den Einsatz in Anwendungen wie Aggregaten. Der HC7 verstärkt den Eingangsdruck auf einen höheren Ausgangsdruck und kompensiert automatisch den Ölverbrauch, um den Hochdruck konstant zu halten. Die Einstellung des Ausgangsdrucks erfolgt über die Regelung des Eingangsdrucks. Mit der Auswahl an verschiedenen Hochdruckadaptern ergibt sich eine Vielzahl von Anschlussmöglichkeiten bei Verwendung des M22x1,5 als HD-…
Dateityp: application/pdf
Verlinkt bei:
miniBOOSTER HC7 Beschreibung Der HC7 ist ein sehr kompaktes Hochdruckgerät, das bei einem Gewicht von nur 1,5 kg Drücke bis zu 2.000 bar liefern kann. Zudem eignet er sich ideal für den Einsatz in Anwendungen wie Aggregaten. Der HC7 verstärkt den Eingangsdruck auf einen höheren Ausgangsdruck und kompensiert automatisch den Ölverbrauch, um den Hochdruck konstant zu halten. Die Einstellung des Ausgangsdrucks erfolgt über die Regelung des Eingangsdrucks. Mit der Auswahl an verschiedenen Hochdruckadaptern ergibt sich eine Vielzahl von Anschlussmöglichkeiten bei Verwendung des M22x1,5 als HD-…
Dateityp: application/pdf
Verlinkt bei:
GEAR PUMPS Group 2 l Technical Information 77C 33M 55K 50C 100Y 66M 88Y 66M 88Y GROUP 2 GEAR PUMPS I TECHNICAL INFORMATION2 Turolla - L1016341 • September 2013 • Rev C History of revisions Date Page Changed Rev. 28, June 2010 - First edition A 24, Feb 2011 1, 2, 12, 44 Covers to blue color, Turolla brand name, Biofluids deleted. B 30, Sept 2013 ALL Layout and options lists C Reference documents Title Type Order number General Aluminum Gear Pumps and Motors Technical Information L1016238 Group 1 Gear Pumps Technical Information L1016399 Group 3 Gear Pumps Technical Information L1016456 Group 1,…
Dateityp: application/pdf
Verlinkt bei:
GEAR PUMPS Group 2 l Technical Information 77C 33M 55K 50C 100Y 66M 88Y 66M 88Y GROUP 2 GEAR PUMPS I TECHNICAL INFORMATION2 Turolla - L1016341 • September 2013 • Rev C History of revisions Date Page Changed Rev. 28, June 2010 - First edition A 24, Feb 2011 1, 2, 12, 44 Covers to blue color, Turolla brand name, Biofluids deleted. B 30, Sept 2013 ALL Layout and options lists C Reference documents Title Type Order number General Aluminum Gear Pumps and Motors Technical Information L1016238 Group 1 Gear Pumps Technical Information L1016399 Group 3 Gear Pumps Technical Information L1016456 Group 1,…
Dateityp: application/pdf
Verlinkt bei:
Group 1 Gear Pumps Technical Information OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP ™ 2 OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP ™ L1016399 • June 2010 • Rev A Group 1 Gear Pumps Technical Information Table of revisions Date Page Changed Rev. 24, June 2010 - First edition A Literature reference for gear products Title Type Order number General Aluminum Gear Pumps and Motors Technical Information L1016238 Group 2 Gear Pumps Technical Information L1016341 Group 3 Gear Pumps Technical Information L1016456 Group 1, 2 and 3 Gear Motors Technical Information L1016082 Hydraulic Fluids…
Dateityp: application/pdf
Verlinkt bei:
Group 1 Gear Pumps Technical Information OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP ™ 2 OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP ™ L1016399 • June 2010 • Rev A Group 1 Gear Pumps Technical Information Table of revisions Date Page Changed Rev. 24, June 2010 - First edition A Literature reference for gear products Title Type Order number General Aluminum Gear Pumps and Motors Technical Information L1016238 Group 2 Gear Pumps Technical Information L1016341 Group 3 Gear Pumps Technical Information L1016456 Group 1, 2 and 3 Gear Motors Technical Information L1016082 Hydraulic Fluids…
Dateityp: application/pdf
Verlinkt bei:
Group 1 Gear Pumps Technical Information OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP ™ 2 OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP ™ L1016399 • June 2010 • Rev A Group 1 Gear Pumps Technical Information Table of revisions Date Page Changed Rev. 24, June 2010 - First edition A Literature reference for gear products Title Type Order number General Aluminum Gear Pumps and Motors Technical Information L1016238 Group 2 Gear Pumps Technical Information L1016341 Group 3 Gear Pumps Technical Information L1016456 Group 1, 2 and 3 Gear Motors Technical Information L1016082 Hydraulic Fluids…
Dateityp: application/pdf
Verlinkt bei:
HC3- H- NG10 miniBOOSTER Description The HC3- H- NG10 is a variant of the HC3 with the topside and the B port closed, not needing a top plate. It is designed for use in NG10 (D05) stacking manifold systems. Like the other HC3 units, the HC3- H- NG10 is a compact unit weighing only 3.4 kg. Maximum outlet pressure is 500 bar in standard versions. Adjustments of the outlet pressure is carried out by varying the supplied pressure. Flow rates Intensification factor i Max. outlet flow l/ min Max. inlet flow l/ min 1.2 1.2 8.0 1.5 1.0 8.0 2.0 2.0 12.0 2.8 2.2 13.0 3.2 2.5 15.0 4.0 2.0 14.0 5.0 1.6…
Dateityp: application/pdf
Verlinkt bei: