Bulletin 947070-B OILGEAR TYPE “PVM” PUMPS - -011/-014/-022/-025/-034/-046/ -064/-065/-075/-076/-098/-130 SERVICE INSTRUCTIONS Figure 1. Typical Oilgear “PVM” Open Loop Pump PURPOSE OF INSTRUCTIONS These instructions will simplify the installation, operation, maintenance and troubleshooting of Oilgear type “PVM” pumps. Become familiar with the construction, principle of operation and characteristics of your pump to help you attain satisfactory performance, reduce shut- down and increase the pump's service life. Some pumps have been modified from those described in this bulletin and other…
File type: application/pdf
Referenced at:
Bulletin 47070-C PVM Open Loop Pumps Copyright 2006 n The Oilgear Company n All Rights Reserved2 Ta bl e of C on te nt s Table of Contents Performance Assurance page 3 Features and Benefits 4-5 Specifications 6 Dimensions and Weights 7 Pressure Pick-ups 7 Controls Pressure Compensator 8 Standard Load Sense w/Pressure Compensator Override 8 Proportional Electrohydraulic Pressure Compensator 8 Inverse Proportional Electrohydraulic Pressure Compensator 8 Adjustable Load Sense w/Pressure Compensator Override 9 Adjustable Load Sense w/Pressure Bleed-off & Pressure Compensator Override 9 Soft Start…
File type: application/pdf
Referenced at:
Die Axialkolbenpumpen der Baureihe PVM wurden für den wertorientierten Ingenieur entwickelt. Die Pumpen sind durch unsere exklusive „hart-auf-hart” Rotationsgruppe und die bewährte hydro- dynamische Lagerung für eine lange Lebensdauer ausgelegt. Unter „hart-auf-hart” verbirgt sich, daß alle internen Laufflächen eine gehärtete Oberfläche haben. Dies bietet größere Beständigkeit gegen hoch kontaminierte Hydraulikflüssigkeiten und Einsatzfähigkeit in diesen Flüssigkeiten. Die hydrodynamischen Lager aus Verbundwerkstoff widerstehen höheren Temperaturen,bieten unbegrenzte Lagerlebensdauer und…
File type: application/pdf
Referenced at:
Die Axialkolbenpumpen der Baureihe PVM wurden für den wertorientierten Ingenieur entwickelt. Die Pumpen sind durch unsere exklusive „hart-auf-hart” Rotationsgruppe und die bewährte hydro- dynamische Lagerung für eine lange Lebensdauer ausgelegt. Unter „hart-auf-hart” verbirgt sich, daß alle internen Laufflächen eine gehärtete Oberfläche haben. Dies bietet größere Beständigkeit gegen hoch kontaminierte Hydraulikflüssigkeiten und Einsatzfähigkeit in diesen Flüssigkeiten. Die hydrodynamischen Lager aus Verbundwerkstoff widerstehen höheren Temperaturen,bieten unbegrenzte Lagerlebensdauer und…
File type: application/pdf
Referenced at:
T E C H N I C A L C A T A L O G MOTORS MV HYDRAULIC MOTORS Motors MV - Hydraulic Motors POCLAIN HYDRAULICS 2 26/04/2013 MV2 MV3 Displacement Maximum cm³/rev [in³/rev.] From 35 [2.14] to 53 [3.23] From 55 [3.36] to 65 [3.973] Minimum cm³/rev [in³/rev.] From 17 [1.04] to 41 [2.50] 25 [1.53] Speed at max. displacement rpm 3 200 at mini. displacement rpm 4 200 Output torque N.m [lbf.in] 211 [1868] 256 [2266] Max. pressure Continuous bar [PSI] 250 [3 626] Peak bar [PSI] 350 [5 076] Case pressure Continuous bar [PSI] 1,5 [21,7] Maximum (cold start) bar [PSI] 2,5 [36.2] Mounting flange and shaft SAE…
File type: application/pdf
Referenced at:
T E C H N I C A L C A T A L O G MSE03 HYDRAULIC MOTORS 2 20/03/2009 Modular hydraulic motors MSE03 POCLAIN HYDRAULICS CHARACTERISTICS 1 450 [27.4] 225 [13.7] 716 [364] 155 2 500 [30.5] 250 [15.2] 795 [404] 140 166 183 11 [15] 350 [5 076]22 [30] 16.5 [22] C am s w ith eq ua l l ob es Theoretical torque at 100 bar at 1000 PSI Nm [lb.ft] Max. pressure bar [PSI] Max.power kW [HP]cm³/tr [cu.in/rev.]cm³/tr [cu.in/rev.] preferred kW [HP] non-preferred kW [HP] Max.speed tr/min[RPM]tr/min[RPM] First displacement Second displacement Motor inertia = 0.01 kg.m² Noise emissions = 60 dBA 20/03/2009 3…
File type: application/pdf
Referenced at:
N-8 InternetContact Details Before using the product, please check the guide pages at the front of this catalog. http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals NDR Series Rotor Pack Features Low noise Achieves a noise level of no greater than 60 dB (A) and there is no need to worry about hydraulic noise even at factories in residential areas. Compact design Minimum size designs for both the vertical and horizontal models make mounting design easier. High reliability The fully enclosed structure with no shaft protruding from the casing eliminates the…
File type: application/pdf
Referenced at:
N-15 N U N IT E Q U IP M E N T InternetContact Details Before using the product, please check the guide pages at the front of this catalog. http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals Model code Voltage V Frequency Hz Operating current A Input W Locked current A Starting current A Coil and protection type Lead wire DCR10B-10 200 50 0.120 16.0 0.170 0.170 Shading coil type (with impedance protector) Heat resisting flat two-core vinyl cable • Length: 1 m • External dimensions: 5.4 × 2.7 mm • Wire diameter: 0.75 mm2 200 60 0.110 15.0 0.150 0.150 220 60…
File type: application/pdf
Referenced at:
N-15 N U N IT E Q U IP M E N T InternetContact Details Before using the product, please check the guide pages at the front of this catalog. http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals Model code Voltage V Frequency Hz Operating current A Input W Locked current A Starting current A Coil and protection type Lead wire DCR10B-10 200 50 0.120 16.0 0.170 0.170 Shading coil type (with impedance protector) Heat resisting flat two-core vinyl cable • Length: 1 m • External dimensions: 5.4 × 2.7 mm • Wire diameter: 0.75 mm2 200 60 0.110 15.0 0.150 0.150 220 60…
File type: application/pdf
Referenced at:
File type: application/pdf
Referenced at: