The only full range of hydraulic intensifying solutions MINIMUM SIZE – MAXIMUM POWER Outlet Pressure bar Average outlet flow (l/min) Inlet pressure (bar) Inlet flow (l/min) Connection Weight (kg) Ratio Model: Steel Model: Stainless steel Comments Models 24 - 800 0.3 - 0.5 20 - 207 2.0 - 8.0 • Tube • Flange • Cartridge 0.7 1.2 - 7.5 HC1 HC1W 24 - 800 0.3 - 2.5 20 - 207 2.0 - 15.0 • Tube • Flange • Cartridge 1.0 1.2 - 20.0 HC2 HC2W 24 - 800 0.7 - 11.0 20 - 207 2.0 - 15.0 • Tube • Flange 3.8 1.2 - 20.0 HC2D HC2DW 80 - 1380 1.5 - 5.0 20 - 207 2.0 - 14.0 8.0 4.0 - 13.0 HC2DHW • Tube • Flange 20 -…
Dateityp: application/pdf
Verlinkt bei:
Änderungen vorbehalten · 20.95-d · 0215 Seite 1www.argo-hytos.com E 328 · E 498 Tankeinbau · Anschluss bis G1½ bzw. SAE 2 · Nennvolumenstrom bis 600 l/min Rücklauf-Saugfilter Beschreibung Einsatzbereich In mobilen Geräten mit hydrostatischem Antrieb (geschlossener Kreis) und Arbeitshydraulik (offener Kreis), bei denen unter allen Betriebsbedingungen der Rücklaufstrom größer als der Volumen- strom der Füllpumpe des Hydrostaten ist. Leistungsmerkmale Verschleißschutz: Durch Filterelemente, die bei Vollstromfiltration höchste Anfor- derungen an die Reinheitsklasse erfüllen. Saugfilterfunktion:…
Dateityp: application/pdf
Verlinkt bei:
Änderungen vorbehalten · 20.95-d · 0215 Seite 1www.argo-hytos.com E 328 · E 498 Tankeinbau · Anschluss bis G1½ bzw. SAE 2 · Nennvolumenstrom bis 600 l/min Rücklauf-Saugfilter Beschreibung Einsatzbereich In mobilen Geräten mit hydrostatischem Antrieb (geschlossener Kreis) und Arbeitshydraulik (offener Kreis), bei denen unter allen Betriebsbedingungen der Rücklaufstrom größer als der Volumen- strom der Füllpumpe des Hydrostaten ist. Leistungsmerkmale Verschleißschutz: Durch Filterelemente, die bei Vollstromfiltration höchste Anfor- derungen an die Reinheitsklasse erfüllen. Saugfilterfunktion:…
Dateityp: application/pdf
Verlinkt bei:
SAUER BIBUS 1 Prüfprotokoll ICVD W-581410(für Prüfung als Motor) Kunde: BvL Anwendung: 4WD Fabriknummer: Deckelnummer: 50.20.1395 Voreinstellungen Schaltplan Einbaulage Spannung 24 VDC soll ist Messstelle M3 und M4 angeschlossen Manometer 600 bar Getriebeölstand Prüfen SAE80W90 GL5 bis Unterkante Kontrollschraube 3,5 l Fördervolumen: Speisedruck: 100 ± 1 l/min 30 + 1 bar 35 ± 1 l/min l/min bar l/min Prüftemperatur 50 ± 5 °C °C Übersetzung I = 1:1,24 Gehäusedruck während Prüfung > 2,5 bar Seite A Qmax bei 200 ± 10 bar Drehmoment 348 ± 20 U/min 884 ± 20 Nm U/min Nm SAUER BIBUS 2 Seite B Qmax bei…
Dateityp: application/pdf
Verlinkt bei:
WALTERSCHEID Prüfprotokoll ICVD W-581358 (für Prüfung als Motor) Kunde: Maurer Türkheim Anwendung: Kehrblasgerät TJS 630 Slave Fabriknummer: Deckelnummer: 50.20.1045 Voreinstellungen Schaltplan Einbaulage soll ist Messstelle M3 und M4 angeschlossen Manometer 600 bar Getriebeölstand Prüfen SAE80W90 GL5 bis Unterkante Kontrollschraube 3,5 l Fördervolumen: Speisedruck: 100 ± 1 l/min 35 + 1 bar 35 ± 1 l/min l/min bar l/min Prüftemperatur 50 ± 5 °C °C Übersetzung I = 1:1,64 Gehäusedruck während Prüfung > 2,5 bar Seite A Qmax bei 200 ± 10 bar Drehmoment 160 ± 20 U/min 1915 ± 20 Nm U/min Nm Seite B…
Dateityp: application/pdf
Verlinkt bei:
V B B R A K E V A LV E S T E C H N I C A L C A T A L O G VB Brake valves POCLAIN HYDRAULICS 2 27/03/2017 HYDRAULIC BRAKE SYSTEM Tank Pump Accumulators store energy for power off braking. Auxiliaries Emergency / Parking brake valve controls the SAHR brake to provide emergency and parking brake functions. SAHR (Spring Applied, Hydraulics Release brake) Accumulator charging valve ensures the pressure is available in the accumulator(s) to operate the brake(s). HASR (Hydraulic Applied Spring Release) Service braking valve provides HASR brake control to provide dynamic brake functions. FRONT REAR…
Dateityp: application/pdf
Verlinkt bei:
V B B R A K E V A LV E S T E C H N I C A L C A T A L O G VB Brake valves POCLAIN HYDRAULICS 2 27/03/2017 HYDRAULIC BRAKE SYSTEM Tank Pump Accumulators store energy for power off braking. Auxiliaries Emergency / Parking brake valve controls the SAHR brake to provide emergency and parking brake functions. SAHR (Spring Applied, Hydraulics Release brake) Accumulator charging valve ensures the pressure is available in the accumulator(s) to operate the brake(s). HASR (Hydraulic Applied Spring Release) Service braking valve provides HASR brake control to provide dynamic brake functions. FRONT REAR…
Dateityp: application/pdf
Verlinkt bei:
1 Prüfprotokoll ICVD W-581334 (für Prüfung als Motor) Kunde: Kramer Anwendung: Telehandler 6030C Fabriknummer: Deckelnummer: 50.20.0815 Voreinstellungen Schaltplan Einbaulage: 90° stehend Spannung 12 VDC soll ist Messstelle M3 und M4 angeschlossen Manometer 600 bar Getriebeölstand Prüfen SAE80W90 GL5 bis Unterkante Kontrollschraube 3,5 l Fördervolumen: Speisedruck: 85 ± 1 l/min 32 + 1 bar 35 ± 1 l/min l/min bar l/min Prüftemperatur 50 +- 5 °C °C Übersetzung I = 1:1,056 Gehäusedruck während Prüfung > 2,5 bar Seite A Qmax bei 200 ± 10 bar Drehmoment 400 ± 20 U/min 605 ± 20 Nm U/min Nm 2 Seite B…
Dateityp: application/pdf
Verlinkt bei:
WALTERSCHEID Prüfprotokoll ICVD W-581357 (für Prüfung als Motor) Kunde: Maurer Türkheim Anwendung: Kehrblasgerät TJS 630 Master Fabriknummer: Deckelnummer: 50.20.1275 Voreinstellungen Schaltplan Einbaulage soll ist Messstelle M3 und M4 angeschlossen Manometer 600 bar Getriebeölstand Prüfen SAE80W90 GL5 bis Unterkante Kontrollschraube 3,5 l Fördervolumen: Speisedruck: 100 ± 1 l/min 35 + 1 bar 35 ± 1 l/min l/min bar l/min Prüftemperatur 50 +- 5 °C °C Übersetzung I = 1:1,64 Gehäusedruck während Prüfung > 2,5 bar Seite A Qmax bei 200 ± 10 bar Drehmoment 160 ± 20 U/min 1915 ± 20 Nm U/min Nm Seite B…
Dateityp: application/pdf
Verlinkt bei:
SAUER BIBUS 1 Prüfprotokoll ICVD W-581381 (für Prüfung als Motor) Kunde: Kramer Anwendung: Telehandler 352 Fabriknummer: Deckelnummer: 50.20.0815 Voreinstellungen Schaltplan Einbaulage Spannung 12 VDC soll ist Messstelle M3 und M4 angeschlossen Manometer 600 bar Getriebeölstand Prüfen SAE80W90 GL5 bis Unterkante Kontrollschraube 3,5 l Fördervolumen: Speisedruck: 100 ± 1 l/min 30 + 1 bar 35 ± 1 l/min l/min bar l/min Prüftemperatur 50 ± 5 °C °C Übersetzung I = 1:1,39 Gehäusedruck während Prüfung > 2,5 bar Seite A Qmax bei 200 ± 10 bar Drehmoment 310 ± 20 U/min 512± 20 Nm U/min Nm SAUER BIBUS 2…
Dateityp: application/pdf
Verlinkt bei: