T E C H N I C A L C A T A L O G MS02 - MSE02 HYDRAULIC MOTORS 2 02/07/2013 Hydraulic motors MS02 - MSE02 new generation POCLAIN HYDRAULICS CHARACTERISTICS Motor inertia = 0.01 kg.m² Noise emissions = 60 dBA 8 172 [10,5] 86 [5,2] 273 [139] 590* 580* 590* 0 213 [13,0] 107 [6,5] 339 [172] 470* 470* 475* 1 235 [14,3] 118 [7,2] 374 [190] 430* 425* 430* 2 255 [15,6] 128 [7,8] 405 [206] 395* 390* 395* 0 332 [20,2] 166 [10,1] 528 [268] 265* 325* 340* 1 364 [22,2] 182 [11,1] 579 [294] 245* 300* 310* 2 398 [24,3] 199 [12,1] 633 [322] 225* 270* 285* 86 [5,2] 128 [7,8] 85 [5,2] 107 [6,5] 133 [8,1] 199…
Dateityp: application/pdf
Verlinkt bei:
T E C H N I C A L C A T A L O G MS02 - MSE02 HYDRAULIC MOTORS 2 02/07/2013 Hydraulic motors MS02 - MSE02 new generation POCLAIN HYDRAULICS CHARACTERISTICS Motor inertia = 0.01 kg.m² Noise emissions = 60 dBA 8 172 [10,5] 86 [5,2] 273 [139] 590* 580* 590* 0 213 [13,0] 107 [6,5] 339 [172] 470* 470* 475* 1 235 [14,3] 118 [7,2] 374 [190] 430* 425* 430* 2 255 [15,6] 128 [7,8] 405 [206] 395* 390* 395* 0 332 [20,2] 166 [10,1] 528 [268] 265* 325* 340* 1 364 [22,2] 182 [11,1] 579 [294] 245* 300* 310* 2 398 [24,3] 199 [12,1] 633 [322] 225* 270* 285* 86 [5,2] 128 [7,8] 85 [5,2] 107 [6,5] 133 [8,1] 199…
Dateityp: application/pdf
Verlinkt bei:
miniBOOSTER HC22 Beschreibung Der HC22 ist ein kompaktes Gerät mit einem Gewicht von nur 2,3 kg. Er eignet sich hervorragend für eine Vielzahl von Anwendungen, bei denen der Aufbau und die Aufrechterhaltung von Hochdruck erforderlich ist. Der HC22 verstärkt den Eingangsdruck auf einen höheren Ausgangsdruck und kompensiert automatisch den Ölverbrauch, um den Hochdruck konstant zu halten. In den HC22 ist ein Druckreduzierventil (PRV) integriert, mit dem der Eingangsdruck zum Verstärkerbereich geregelt werden kann. Optional kann er mit einer Blende ausgestattet werden, um den Eingangsdurchfluss…
Dateityp: application/pdf
Verlinkt bei:
miniBOOSTER HC22 Beschreibung Der HC22 ist ein kompaktes Gerät mit einem Gewicht von nur 2,3 kg. Er eignet sich hervorragend für eine Vielzahl von Anwendungen, bei denen der Aufbau und die Aufrechterhaltung von Hochdruck erforderlich ist. Der HC22 verstärkt den Eingangsdruck auf einen höheren Ausgangsdruck und kompensiert automatisch den Ölverbrauch, um den Hochdruck konstant zu halten. In den HC22 ist ein Druckreduzierventil (PRV) integriert, mit dem der Eingangsdruck zum Verstärkerbereich geregelt werden kann. Optional kann er mit einer Blende ausgestattet werden, um den Eingangsdurchfluss…
Dateityp: application/pdf
Verlinkt bei:
PIM00219 Hybrid Hydraulic System Super Unit (Analog Model) with Flow Switching Function [200V]SUT00D8021-30-B-N0323 [400V]SUT00D8021-21YB-N0324 [200V]SUT00D13021-10-B-N0321 [400V]SUT00D13021-10YB-N0322 [200V]SUT00D15021-10-B-N0365 [400V]SUT00D15021-10YB-N0358 Operation Manual (ORIGINAL INSTRUCTIONS) DAIKIN INDUSTRIES, LTD. Oil Hydraulics Division PIM00219 Introduction Thank you for selecting the SUPER UNIT of DAIKIN Hydraulic System. This operation manual describes how to operate this SUPER UNIT, and maintenance/inspection, troubleshooting procedure and specifications of this system. Before…
Dateityp: application/pdf
Verlinkt bei:
PIM00219 Hybrid Hydraulic System Super Unit (Analog Model) with Flow Switching Function [200V]SUT00D8021-30-B-N0323 [400V]SUT00D8021-21YB-N0324 [200V]SUT00D13021-10-B-N0321 [400V]SUT00D13021-10YB-N0322 [200V]SUT00D15021-10-B-N0365 [400V]SUT00D15021-10YB-N0358 Operation Manual (ORIGINAL INSTRUCTIONS) DAIKIN INDUSTRIES, LTD. Oil Hydraulics Division PIM00219 Introduction Thank you for selecting the SUPER UNIT of DAIKIN Hydraulic System. This operation manual describes how to operate this SUPER UNIT, and maintenance/inspection, troubleshooting procedure and specifications of this system. Before…
Dateityp: application/pdf
Verlinkt bei:
PIM00219 Hybrid Hydraulic System Super Unit (Analog Model) with Flow Switching Function [200V]SUT00D8021-30-B-N0323 [400V]SUT00D8021-21YB-N0324 [200V]SUT00D13021-10-B-N0321 [400V]SUT00D13021-10YB-N0322 [200V]SUT00D15021-10-B-N0365 [400V]SUT00D15021-10YB-N0358 Operation Manual (ORIGINAL INSTRUCTIONS) DAIKIN INDUSTRIES, LTD. Oil Hydraulics Division PIM00219 Introduction Thank you for selecting the SUPER UNIT of DAIKIN Hydraulic System. This operation manual describes how to operate this SUPER UNIT, and maintenance/inspection, troubleshooting procedure and specifications of this system. Before…
Dateityp: application/pdf
Verlinkt bei:
D3 - 2 11141726 • Rev CA• August 2015 DCV03 Solenoid Valves Catalog D 3 - D CV 03 Solenoid Valves • 3 position, 4-way, and 2 position, 4-way directional valves • Cylindrical operating solenoids with separate operating coils – connector can be rotated 90° • 4-land spool – reduced functional dependence on fluid viscosity • Push button manual override • Installation dimensions to ISO 4401- 03-02-0-94 and DIN 24340-A6 DCV 03 directional control valves consist of: housing (1), control spool (5), with two centering springs (4), and cylindrical operating solenoids (2, 3). The three-position…
Dateityp: application/pdf
Verlinkt bei:
CAST IRON GEAR PUMPS AND MOTORS Dolomites Group 3 l Technical Information Orange - CMYK 88%Y 66%M Grey - CMYK 44% Black 77C 33M 55K 50C 100Y 66M 88Y 66M 88Y dolomites 3 I TECHNICAL INFORMATION2 Turolla • September 2016 History of revisions Date Page Changed Rev. March 2015 - First edition - September 2016 - Second edition - © 2016 Turolla ™. All rights reserved. Turolla accepts no responsibility for possible errors in catalogs, brochures and other printed material. Turolla reserves the right to alter its products without prior notice. This also applies to products already ordered provided that…
Dateityp: application/pdf
Verlinkt bei:
CAST IRON GEAR PUMPS AND MOTORS Dolomites Group 3 l Technical Information Orange - CMYK 88%Y 66%M Grey - CMYK 44% Black 77C 33M 55K 50C 100Y 66M 88Y 66M 88Y dolomites 3 I TECHNICAL INFORMATION2 Turolla • September 2016 History of revisions Date Page Changed Rev. March 2015 - First edition - September 2016 - Second edition - © 2016 Turolla ™. All rights reserved. Turolla accepts no responsibility for possible errors in catalogs, brochures and other printed material. Turolla reserves the right to alter its products without prior notice. This also applies to products already ordered provided that…
Dateityp: application/pdf