GEAR PUMPS Group 2 l Technical Information 77C 33M 55K 50C 100Y 66M 88Y 66M 88Y GROUP 2 GEAR PUMPS I TECHNICAL INFORMATION2 Turolla - L1016341 • September 2013 • Rev C History of revisions Date Page Changed Rev. 28, June 2010 - First edition A 24, Feb 2011 1, 2, 12, 44 Covers to blue color, Turolla brand name, Biofluids deleted. B 30, Sept 2013 ALL Layout and options lists C Reference documents Title Type Order number General Aluminum Gear Pumps and Motors Technical Information L1016238 Group 1 Gear Pumps Technical Information L1016399 Group 3 Gear Pumps Technical Information L1016456 Group 1,…
Dateityp: application/pdf
Verlinkt bei:
T E C H N I S C H E R K A T A L O G MW50 HYDRAULIKMOTOREN 2 30/09/2011 Hydraulikmotoren - Modulbauweise MW50 POCLAIN HYDRAULICS TECHNISCHE DATEN Für andere Nockenring wenden Sie sich bitte an Ihren Poclain Hydraulics-Anwendungstechniker. Motorträgheit 1 kg.m² H2 H3 H4 4 333 2 833 1 500 [264,3] [172,8] [91,5] 4 333 3000 1 333 [264,3] [183,0] [81,3] 5 000 3 667 1 333 [305,0] [223,7] [81,3] 5 000 3 333 1 667 [305,0] [203,3] [101,7] 5 000 3 000 2 000 [305,0] [183,0] [122,0] 5 167 3 500 1 667 [315,1] [213,5] [101,7] 5 167 3 333 1 834 [315,1] [203,3] [111,9] 6 000 4 000 2 000 [365,9] [244,0] [122,0]…
Dateityp: application/pdf
Verlinkt bei:
T E C H N I S C H E R K A T A L O G MW50 HYDRAULIKMOTOREN 2 30/09/2011 Hydraulikmotoren - Modulbauweise MW50 POCLAIN HYDRAULICS TECHNISCHE DATEN Für andere Nockenring wenden Sie sich bitte an Ihren Poclain Hydraulics-Anwendungstechniker. Motorträgheit 1 kg.m² H2 H3 H4 4 333 2 833 1 500 [264,3] [172,8] [91,5] 4 333 3000 1 333 [264,3] [183,0] [81,3] 5 000 3 667 1 333 [305,0] [223,7] [81,3] 5 000 3 333 1 667 [305,0] [203,3] [101,7] 5 000 3 000 2 000 [305,0] [183,0] [122,0] 5 167 3 500 1 667 [315,1] [213,5] [101,7] 5 167 3 333 1 834 [315,1] [203,3] [111,9] 6 000 4 000 2 000 [365,9] [244,0] [122,0]…
Dateityp: application/pdf
Verlinkt bei:
T E C H N I S C H E R K A T A L O G MW50 HYDRAULIKMOTOREN 2 30/09/2011 Hydraulikmotoren - Modulbauweise MW50 POCLAIN HYDRAULICS TECHNISCHE DATEN Für andere Nockenring wenden Sie sich bitte an Ihren Poclain Hydraulics-Anwendungstechniker. Motorträgheit 1 kg.m² H2 H3 H4 4 333 2 833 1 500 [264,3] [172,8] [91,5] 4 333 3000 1 333 [264,3] [183,0] [81,3] 5 000 3 667 1 333 [305,0] [223,7] [81,3] 5 000 3 333 1 667 [305,0] [203,3] [101,7] 5 000 3 000 2 000 [305,0] [183,0] [122,0] 5 167 3 500 1 667 [315,1] [213,5] [101,7] 5 167 3 333 1 834 [315,1] [203,3] [111,9] 6 000 4 000 2 000 [365,9] [244,0] [122,0]…
Dateityp: application/pdf
Verlinkt bei:
Gear Motors Group 1, 2 and 3 Technical Information 2 520L0568 • Rev. B • 10/2005 © 2005, Sauer-Danfoss. All rights reserved. Printed in Europe. Sauer-Danfoss accepts no responsibility for possible errors in catalogs, brochures and other printed material. Sauer -Danfoss reserves the right to alter its products without prior notice. This also applies to products already ordered provided that such alterations can be made without affecting agreed specifications. All trademarks in this material are properties of their respective owners. Sauer-Danfoss and the Sauer-Danfoss logotype are trademarks of…
Dateityp: application/pdf
Verlinkt bei:
N-8 InternetContact Details Before using the product, please check the guide pages at the front of this catalog. http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals NDR Series Rotor Pack Features Low noise Achieves a noise level of no greater than 60 dB (A) and there is no need to worry about hydraulic noise even at factories in residential areas. Compact design Minimum size designs for both the vertical and horizontal models make mounting design easier. High reliability The fully enclosed structure with no shaft protruding from the casing eliminates the…
Dateityp: application/pdf
Verlinkt bei:
N-8 InternetContact Details Before using the product, please check the guide pages at the front of this catalog. http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals NDR Series Rotor Pack Features Low noise Achieves a noise level of no greater than 60 dB (A) and there is no need to worry about hydraulic noise even at factories in residential areas. Compact design Minimum size designs for both the vertical and horizontal models make mounting design easier. High reliability The fully enclosed structure with no shaft protruding from the casing eliminates the…
Dateityp: application/pdf
Verlinkt bei:
N-8 InternetContact Details Before using the product, please check the guide pages at the front of this catalog. http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals NDR Series Rotor Pack Features Low noise Achieves a noise level of no greater than 60 dB (A) and there is no need to worry about hydraulic noise even at factories in residential areas. Compact design Minimum size designs for both the vertical and horizontal models make mounting design easier. High reliability The fully enclosed structure with no shaft protruding from the casing eliminates the…
Dateityp: application/pdf
Verlinkt bei:
T E C H N I C A L C A T A L O G P M V 0 V A R IA B LE D IS P LA C E M E N T P U M P C LO S E D LO O P C IR C U IT 2 29/03/2017 PMV0 - Variable displacement pump POCLAIN HYDRAULICS OVERVIEW PMV0 is a variable displacement, axial piston pump, with swashplate system, for closed loop hydrostatic transmissions. It provides a continuously variable flow rate between zero and maximum in forward and reverse direction. Flow rate is proportional to rotation speed and swashplate angle. It can feature a charge pump to keep the circuit pressurised. This avoids risk of cavitations and ensures a good…
Dateityp: application/pdf
Verlinkt bei:
T E C H N I C A L C A T A L O G P M V 0 V A R IA B LE D IS P LA C E M E N T P U M P C LO S E D LO O P C IR C U IT 2 29/03/2017 PMV0 - Variable displacement pump POCLAIN HYDRAULICS OVERVIEW PMV0 is a variable displacement, axial piston pump, with swashplate system, for closed loop hydrostatic transmissions. It provides a continuously variable flow rate between zero and maximum in forward and reverse direction. Flow rate is proportional to rotation speed and swashplate angle. It can feature a charge pump to keep the circuit pressurised. This avoids risk of cavitations and ensures a good…
Dateityp: application/pdf
Verlinkt bei: