P L H Y D R A U LIC P U M P S T E C H N I C A L C A T A L O G 2 23/05/2017 PL Hydraulic Pumps POCLAIN HYDRAULICS CHARACTERISTICS Cont.: Continuous operation. Int.: Intermittent operation. (*): Theoretical data. Efficiency values must be taken into account when calculating the power absorbed by the pump. H F OL 6 B 1 2 T 3 1 C 3 P 0 0 0 0 1 2 S 3 4 0 51 2 3 54 4 1 2 F 32 7 2 x 17.5 [2 x 1.07] 2 700 3 100 2 x 47 [2 x 12.42] 2 x 54 [2 x 14.27] 55 [74] 81 [109] 2 x 20 [2 x 1.22] 2 600 3 000 2 x 52 [2 x 13.74] 2 x 60 [2 x 15.85] 61 [82] 90 [121] 2 x 22 [2 x 1.34] 2 500 2 900 2 x 55 [2 x 14.53] 2 x…
File type: application/pdf
Referenced at:
T E C H N I C A L C A T A L O G PL HYDRAULIC PUMPS 2 21/02/2006 PL Hydraulic Pumps POCLAIN HYDRAULICS CHARACTERISTICS Cont.: Continuous operation. Int.: Intermittent operation. (*): Theoretical data. Efficiency values must be taken into account when calculating the power absorbed by the pump. H F OL 6 B 1 2 T 3 1 C 3 P 0 0 0 0 1 2 S 3 4 0 51 2 3 54 4 1 2 F 32 7 2 x 17.5 [2 x 1.07] 2 700 3 100 2 x 47 [2 x 12.42] 2 x 54 [2 x 14.27] 55 [74] 81 [109] 2 x 20 [2 x 1.22] 2 600 3 000 2 x 52 [2 x 13.74] 2 x 60 [2 x 15.85] 61 [82] 90 [121] 2 x 22 [2 x 1.34] 2 500 2 900 2 x 55 [2 x 14.53] 2 x 64 [2 x…
File type: application/pdf
Referenced at:
Ölablass (Hydraulik) oil drain (hydraulic) Ölablass (Mechanik) oil drain (mechanic) Querspülung cross flushing Entlüftungsventil air valve Forward drive Vorwärtsfahrt Backward drive Rückwärtsfahrt Entlüftungsventil air valve AMP-Superseal 1,5 Series Gehaeuse 282105 Gegenstecker Gehaeuse 282087 24 Impulse/Umdrehung 12 Volt Querspülung cross flushing Öleinlass / Ölkontrolle (Mechanik) oil filter plug / oil check (mechanic) Entlüftungsventil air valve Ölablaß (Mechanik) oil drain (mechanic) Einbaulage: 15° fitting position: 15° Ölablaß (Mechanik) oil drain (mechanic) Entlüftungsventil air valve…
File type: application/pdf
Referenced at:
T E C H N I C A L C A T A L O G MW50 HYDRAULIC MOTORS 2 30/09/2011 Modular hydraulic motors MW50 POCLAIN HYDRAULICS CHARACTERISTICS For other cams, consult your Poclain Hydraulics application engineer. Motor inertia 1 kg.m² H2 H3 H4 4 333 2 833 1 500 [264,3] [172,8] [91,5] 4 333 3000 1 333 [264,3] [183,0] [81,3] 5 000 3 667 1 333 [305,0] [223,7] [81,3] 5 000 3 333 1 667 [305,0] [203,3] [101,7] 5 000 3 000 2 000 [305,0] [183,0] [122,0] 5 167 3 500 1 667 [315,1] [213,5] [101,7] 5 167 3 333 1 834 [315,1] [203,3] [111,9] 6 000 4 000 2 000 [365,9] [244,0] [122,0] [4 178] [4 178] [4 043] [4 043] [4…
File type: application/pdf
Referenced at:
T E C H N I C A L C A T A L O G MW50 HYDRAULIC MOTORS 2 30/09/2011 Modular hydraulic motors MW50 POCLAIN HYDRAULICS CHARACTERISTICS For other cams, consult your Poclain Hydraulics application engineer. Motor inertia 1 kg.m² H2 H3 H4 4 333 2 833 1 500 [264,3] [172,8] [91,5] 4 333 3000 1 333 [264,3] [183,0] [81,3] 5 000 3 667 1 333 [305,0] [223,7] [81,3] 5 000 3 333 1 667 [305,0] [203,3] [101,7] 5 000 3 000 2 000 [305,0] [183,0] [122,0] 5 167 3 500 1 667 [315,1] [213,5] [101,7] 5 167 3 333 1 834 [315,1] [203,3] [111,9] 6 000 4 000 2 000 [365,9] [244,0] [122,0] [4 178] [4 178] [4 043] [4 043] [4…
File type: application/pdf
Referenced at:
M S 05 - M S E 05 H Y D R A U LIC M O TO R S T E C H N I C A L C A T A L O G 2 12/12/2013 Modular hydraulic motors MS05 - MSE05 POCLAIN HYDRAULICS CHARACTERISTICS 6 260 [15,9] 130 [7,9] 413 [210] 265 8 376 [22,9] 188 [11,5] 598 [304] 250 0 468 [28,5] 234 [14,3] 744 [378] 240 1 514 [31,3] 257 [15,7] 817 [416] 220 2 560 [34,2] 280 [17,1] 890 [453] 200 8 503 [30.7] 251.5 [15.3] 800 [407] 200 0 625 [38,1] 312.5 [19,1] 994 [505] 190 1 688 [42,0] 344 [21,0] 1094 [556] 175 2 750 [45,7] 375 [22,9] 1193 [606] 160 280 [17,1] 138 [8,4] 234 [14,3] 188 [11,5] 257 [15,7] 188 [11,5] 280 [17,1] 188 [11,5] 374…
File type: application/pdf
Referenced at:
HC6D2W miniBOOSTER Description The HC6D2W is a dual media stainless steel 316 L unit which is capable of delivering up to 28 l/ min flow on the high- pressure end. Like other miniBOOSTER models, the HC6D2W raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. Relative to its flow capability, the HC6D2W is a compact unit weighing 24 kg. Flow rates Intensification factor i Max. outlet flow l/ min Max. inlet flow l/ min 1.0 28.1 30…
File type: application/pdf
Referenced at:
T E C H N I C A L C A T A L O G MS125 HYDRAULIC MOTORS Modular hydraulic motors MS125 POCLAIN HYDRAULICS 20/08/2012 2 CHARACTERISTICS Motor inertia 2 kg.m² 450 420 [6 527] [6 092] 380 335 [5 511] [4 859] 320 280 [4 641] [4 061] 7 500 [457.4] 380 335 5 000 [305.0] [5 511] [4 859] 240 [8 086] [322][10 107] [12 128] [10 107] 240 [322] 30 30 160 50 160 [215] 40[215] A 12 500 [762.4] 19 875 8 10 000 [609.9] 15 9005 000 [305.0] 0 12 500 [762.4] 19 8756 250 [381.2] 2 15 000 [914.9] 23 8507 500 [457.4] 50 40 30 30 C am s w it h eq u a l l o b es C am s w it h u n eq u al lo b e s Max. pressure 1 2 bar…
File type: application/pdf
Referenced at:
miniBOOSTER HC6D2W Beschreibung Der HC6D2W ist ein Zwei- Medien- Gerät aus Edelstahl 316 L, das am Hochdruckende eine Fördermenge von bis zu 28 l/ min bereitstellen kann. Wie andere miniBOOSTER- Modelle auch, verstärkt der HC6D2W den Eingangsdruck auf einen höheren Ausgangsdruck und kompensiert automatisch den Ölverbrauch, um den Hochdruck konstant zu halten. Die Einstellung des Ausgangsdrucks erfolgt über die Regelung des Eingangsdrucks. Gemessen an seiner Förderleistung ist der HC6D2W ein kompaktes Gerät, das nur 24 kg wiegt. Durchflussmenge Verstärkungsfaktor i Max. Ausgangsdurchfluss l/…
File type: application/pdf
Referenced at:
HC6H miniBOOSTER Description The HC6H is an ultra high- pressure unit which is capable of delivering up to 5,000 bar and 1.0 l/ min flow on the high- pressure end. Like other miniBOOSTER models, the HC6H raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. Relative to its flow capability, the HC6H is a compact unit weighing only 11.0 kg. Flow rates Intensification factor i Approx. outlet flow l/ min Max. inlet flow l/ min 6.2 7.0…
File type: application/pdf
Referenced at: