HC3-9 miniBOOSTER Description HC3-9 is a compact hydraulic cartridge miniBOOSTER unit weighing only 1.3 kg. It is ideal for use in applications where it is desirable to mount the unit on or in a manifold, cylinder, or other device. The HC3-9 raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. Flow rates Intensification factor i Max. outlet flow l/ min Max. inlet flow l/ min 1.2 1.2 8.0 1.5 1.0 8.0 2.0 2.0 12.0 2.8 2.2 13.0 3.2…
Dateityp: application/pdf
Verlinkt bei:
HC3- PVG32 miniBOOSTER Description The HC3- PVG32 is a compact unit weighing only 4.0 kg. It is ideal for use in a variety of applications where building and maintaining high pressure is required. The HC3- PVG32 raises supplied pressure to a higher outlet pressure and automatically conpensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. Flow rates Intensification factor i Max. outlet flow l/ min Max. inlet flow l/ min 1.2 1.2 8.0 1.5 1.0 8.0 2.0 2.0 12.0 2.8 2.2 13.0 3.2 2.5 15.0 4.0 2.0 14.0 5.0 1.6…
Dateityp: application/pdf
Verlinkt bei:
HC7-9 miniBOOSTER Description The HC7-9 is a very compact high- pressure unit capable of delivering pressure up to 2,000 bar weighing only 1.3 kg. It is ideal for use in applications where it is desirable to mount the unit on or in a manifold, cylinder, or other device. The HC7-9 raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. Flow rates Intensification factor i Max. outlet flow l/ min Max. inlet flow l/ min 5.0 1.6 14.0 6.6…
Dateityp: application/pdf
Verlinkt bei:
HC3- PVG32 miniBOOSTER Description The HC3- PVG32 is a compact unit weighing only 4.0 kg. It is ideal for use in a variety of applications where building and maintaining high pressure is required. The HC3- PVG32 raises supplied pressure to a higher outlet pressure and automatically conpensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. Flow rates Intensification factor i Max. outlet flow l/ min Max. inlet flow l/ min 1.2 1.2 8.0 1.5 1.0 8.0 2.0 2.0 12.0 2.8 2.2 13.0 3.2 2.5 15.0 4.0 2.0 14.0 5.0 1.6…
Dateityp: application/pdf
Verlinkt bei:
HC3- H- NG10 miniBOOSTER Description The HC3- H- NG10 is a variant of the HC3 with the topside and the B port closed, not needing a top plate. It is designed for use in NG10 (D05) stacking manifold systems. Like the other HC3 units, the HC3- H- NG10 is a compact unit weighing only 3.4 kg. Maximum outlet pressure is 500 bar in standard versions. Adjustments of the outlet pressure is carried out by varying the supplied pressure. Flow rates Intensification factor i Max. outlet flow l/ min Max. inlet flow l/ min 1.2 1.2 8.0 1.5 1.0 8.0 2.0 2.0 12.0 2.8 2.2 13.0 3.2 2.5 15.0 4.0 2.0 14.0 5.0 1.6…
Dateityp: application/pdf
Verlinkt bei:
HC2-9 miniBOOSTER Description HC2-9 is a compact hydraulic cartridge miniBOOSTER unit weighing only 1.0 kg. It is ideal for use in a varitey of special applications where it is desirable to mount the unit on or in a manifold, cylinder, or other device. The HC2-9 raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. Flow rates Intensification factor i Max. outlet flow l/ min Max. inlet flow l/ min 1.2 1.2 8.0 1.5 1.0 8.0 2.0 2.0…
Dateityp: application/pdf
Verlinkt bei:
HC3-9 miniBOOSTER Description HC3-9 is a compact hydraulic cartridge miniBOOSTER unit weighing only 1.3 kg. It is ideal for use in applications where it is desirable to mount the unit on or in a manifold, cylinder, or other device. The HC3-9 raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. Flow rates Intensification factor i Max. outlet flow l/ min Max. inlet flow l/ min 1.2 1.2 8.0 1.5 1.0 8.0 2.0 2.0 12.0 2.8 2.2 13.0 3.2…
Dateityp: application/pdf
Verlinkt bei:
HC7-9 miniBOOSTER Description The HC7-9 is a very compact high- pressure unit capable of delivering pressure up to 2,000 bar weighing only 1.3 kg. It is ideal for use in applications where it is desirable to mount the unit on or in a manifold, cylinder, or other device. The HC7-9 raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. Flow rates Intensification factor i Max. outlet flow l/ min Max. inlet flow l/ min 5.0 1.6 14.0 6.6…
Dateityp: application/pdf
Verlinkt bei:
® Hydrostatic Transmission BDR High performance and durability Infinitely variable output speed Bidirectional output rota- tion Standard control options Shock valve relief options Industry leading warranty and service support A World Leader in Hydrostatic Transaxles * Axial Piston Pumps & Motors * LSHT Wheel Motors * Electric L&G Systems 1411 South Hamilton Street * Sullivan, IL 61951 * Phone (217) 728-2581 * Fax (217) 728-7665 * www.hydro-gear.com SPECIFICATIONS BDR Charged Non-Charged Pump Displacement in3/rev [cc/rev] 0.62 [10.2] 0.62 [10.2] Motor Displacement in3/rev [cc/rev] 1.33 [21.8]…
Dateityp: application/pdf
Verlinkt bei:
® Hydrostatic Transmission BDR High performance and durability Infinitely variable output speed Bidirectional output rota- tion Standard control options Shock valve relief options Industry leading warranty and service support A World Leader in Hydrostatic Transaxles * Axial Piston Pumps & Motors * LSHT Wheel Motors * Electric L&G Systems 1411 South Hamilton Street * Sullivan, IL 61951 * Phone (217) 728-2581 * Fax (217) 728-7665 * www.hydro-gear.com SPECIFICATIONS BDR Charged Non-Charged Pump Displacement in3/rev [cc/rev] 0.62 [10.2] 0.62 [10.2] Motor Displacement in3/rev [cc/rev] 1.33 [21.8]…