T E C H N I S C H E R K A T A L O G M W 14 H Y D R A U LIK M O TO R E N Hydraulikmotore in Modulbauweise MW14 POCLAIN HYDRAULICS 2 07/04/2017 TECHNISCHE DATEN For other cams: Please contact your Poclain Hydraulics application engineer. Bitte beachten Sie die entsprechenden Poclain Hydraulics über die Schluckvolumen-Umschaltung zwischen zweiter und dritter Fahrstufe. Bei Fragen zur Schluckvolumen- Umschaltung während der Fahrt sprechen Sie bitte mit unserer Anwendungstechnik. 1 401 934 467 [85,4] [57,0] [28,5] 2 230 1 486 743 [1 133] [755] [378] 50 40 33 [67] [54] [44] 2 [6 530] 450 120 145 175…
Dateityp: application/pdf
Verlinkt bei:
0 IT MANUALE TECNICO TECHNICAL MANUAL 1 IT CONTENUTI 1 INTRODUZIONE ....................................................................................................................................... 2 1.1 Scopo del documento ........................................................................................................................................ 2 1.2 Avvertenze generali ........................................................................................................................................... 2 1.3 Condizioni di garanzia…
Dateityp: application/pdf
Verlinkt bei:
0 IT MANUALE TECNICO TECHNICAL MANUAL 1 IT CONTENUTI 1 INTRODUZIONE ....................................................................................................................................... 2 1.1 Scopo del documento ........................................................................................................................................ 2 1.2 Avvertenze generali ........................................................................................................................................... 2 1.3 Condizioni di garanzia…
Dateityp: application/pdf
Verlinkt bei:
miniBOOSTER HC2D Beschreibung Der HC2D ist ein doppeltwirkendes Gerät mit hohem Durchfluss, das am Hochdruckende eine Fördermenge von bis zu 11,0 l/ min bereitstellen kann. Wie andere miniBOOSTER- Modelle auch verstärkt der HC2D den Eingangsdruck auf einen höheren Ausgangsdruck und kompensiert automatisch den Ölverbrauch, um den Hochdruck konstant zu halten. Die Einstellung des Ausgangsdrucks erfolgt über die Regelung des Eingangsdrucks. Gemessen an seiner Förderleistung ist der HC2D ein kompaktes Gerät, das nur 3,4 kg wiegt. Durchflussmenge Verstärkungsfaktor i Max. Ausgangsdurchfluss l/ min…
Dateityp: application/pdf
Verlinkt bei:
miniBOOSTER HC2D Beschreibung Der HC2D ist ein doppeltwirkendes Gerät mit hohem Durchfluss, das am Hochdruckende eine Fördermenge von bis zu 11,0 l/ min bereitstellen kann. Wie andere miniBOOSTER- Modelle auch verstärkt der HC2D den Eingangsdruck auf einen höheren Ausgangsdruck und kompensiert automatisch den Ölverbrauch, um den Hochdruck konstant zu halten. Die Einstellung des Ausgangsdrucks erfolgt über die Regelung des Eingangsdrucks. Gemessen an seiner Förderleistung ist der HC2D ein kompaktes Gerät, das nur 3,4 kg wiegt. Durchflussmenge Verstärkungsfaktor i Max. Ausgangsdurchfluss l/ min…
Dateityp: application/pdf
Verlinkt bei:
HC1 miniBOOSTER Description The HC1 is the most compact miniBOOSTER unit weighing only 0.7 kg. It is ideal for use in applications where it is desirable to mount the unit on or in a tool, power pack, or other device. The HC1 raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. Intensification factor i Max. outlet flow l/ min Max. inlet flow l/ min 1.2 0.5 8.0 1.5 0.5 8.0 2.0 0.5 8.0 2.8 0.5 8.0 3.3 0.5 8.0 4.0 0.4 8.0 4.8 0.4 8.0…
Dateityp: application/pdf
Verlinkt bei:
HC1 miniBOOSTER Description The HC1 is the most compact miniBOOSTER unit weighing only 0.7 kg. It is ideal for use in applications where it is desirable to mount the unit on or in a tool, power pack, or other device. The HC1 raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. Intensification factor i Max. outlet flow l/ min Max. inlet flow l/ min 1.2 0.5 8.0 1.5 0.5 8.0 2.0 0.5 8.0 2.8 0.5 8.0 3.3 0.5 8.0 4.0 0.4 8.0 4.8 0.4 8.0…
Dateityp: application/pdf
Verlinkt bei:
miniBOOSTER HC4 Beschreibung Der HC4 eignet sich hervorragend für Anwendungen, in denen ein größeres Volumen von Hochdruckflüssigkeit erforderlich ist. Der HC4 ist ein kompaktes Gerät mit einem Gewicht von nur 3,7 kg, aber einer Fördermenge von bis zu 7,0 l/ min am Ausgang. Wie der HC2 verstärkt er den Eingangsdruck und kompensiert automatisch den Ölverbrauch, um den Hochdruck konstant zu halten. Die Einstellung des Ausgangsdrucks erfolgt über die Regelung des Eingangsdrucks. Durchflussmenge Verstärkungsfaktor i Max. Ausgang l/ min Max. Eingang l/ min 1,3 1,5 25,0 1,5 1,4 25,0 1,8 1,2 25,0 2,1…
Dateityp: application/pdf
Verlinkt bei:
miniBOOSTER HC4 Beschreibung Der HC4 eignet sich hervorragend für Anwendungen, in denen ein größeres Volumen von Hochdruckflüssigkeit erforderlich ist. Der HC4 ist ein kompaktes Gerät mit einem Gewicht von nur 3,7 kg, aber einer Fördermenge von bis zu 7,0 l/ min am Ausgang. Wie der HC2 verstärkt er den Eingangsdruck und kompensiert automatisch den Ölverbrauch, um den Hochdruck konstant zu halten. Die Einstellung des Ausgangsdrucks erfolgt über die Regelung des Eingangsdrucks. Durchflussmenge Verstärkungsfaktor i Max. Ausgang l/ min Max. Eingang l/ min 1,3 1,5 25,0 1,5 1,4 25,0 1,8 1,2 25,0 2,1…
Dateityp: application/pdf
Verlinkt bei:
T E C H N I C A L C A T A L O G MK35 COMPACT MOTORS Compact motors MK35 POCLAIN HYDRAULICS 2 25/06/2013 Methodology : This document is intended for manufacturers of machines that incorporate Poclain Hydraulics products. It describes the technical characteristics of Poclain Hydraulics products and specifies installation conditions that will ensure optimum operation. This document includes important comments concerning safety. They are indicated in the following way: This document also includes essential operating instructions for the product and general information. These are indicated in the…
Dateityp: application/pdf
Verlinkt bei: