Technical Information JS1000 Joystick Base powersolutions.danfoss.com http://powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev May 2017 Minor layout correction 0703 April 2016 Updated to Engineering Tomorrow design 0702 Mar 2014 SAE J1939 Extended Joystick message transmission rate corrected; Danfoss layout-DITA CMS HA Nov 2010 PRO grip is only available in a top mount configuration; Supply voltage is 9 to 32 Vdc GA Mar 2010 Grip options; SAE J1939 CAN Message Specification; Electrical and Environmental Characteristics FA Mar 2010 Features; model code; dimension…
File type: application/pdf
Referenced at:
Technical Information JS1000 Joystick Base powersolutions.danfoss.com http://powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev May 2017 Minor layout correction 0703 April 2016 Updated to Engineering Tomorrow design 0702 Mar 2014 SAE J1939 Extended Joystick message transmission rate corrected; Danfoss layout-DITA CMS HA Nov 2010 PRO grip is only available in a top mount configuration; Supply voltage is 9 to 32 Vdc GA Mar 2010 Grip options; SAE J1939 CAN Message Specification; Electrical and Environmental Characteristics FA Mar 2010 Features; model code; dimension…
File type: application/pdf
Referenced at:
P M 10 V A R IA B LE D IS P LA C E M E N T P U M P C LO S E D LO O P C IR C U IT T E C H N I C A L C A T A L O G 2 15/11/2017 PM10 - Variable displacement pump POCLAIN HYDRAULICS OVERVIEW PM10 is a variable displacement, axial piston pump, with swashplate system, for closed loop hydrostatic transmissions. It provides a continuously variable flow rate between zero and maximum in forward and reverse direction. Flow rate is proportional to rotation speed and swashplate angle. It can feature a charge pump to keep the circuit pressurised. This avoids risk of cavitations and ensures a good…
File type: application/pdf
Referenced at:
P 90 V A R IA B LE D IS P LA C E M E N T P U M P T E C H N I C A L C A T A L O G Variable displacement pump POCLAIN HYDRAULICS 2 20/02/2017 Design Features and options Unit Frame 055 075 100 130 180 250 Displacement cm³/rev[in³/rev.] 55 [3.35] 75 [4.58] 100 [6.10] 130 [7.91] 180 [10.98] 250 [15.25] Flow at rated speed L/min[US gal/min] 215 [57] 270 [71] 330 [87] 403 [106] 468 [124] 575 [152] Torque at maximum displacement N.m/bar[lbf.in/1000 PSI] 0.88 [530] 1.19 [730] 1.59 [970] 2.07 [1 260] 2.87 [1 750] 3.97 [2 433] Mass moment of inertia of rotating component kg.m² [slug.ft²] 0.0060 [0.0044]…
File type: application/pdf
Referenced at:
T E C H N I C A L C A T A L O G PL HYDRAULIC PUMPS 2 21/02/2006 PL Hydraulic Pumps POCLAIN HYDRAULICS CHARACTERISTICS Cont.: Continuous operation. Int.: Intermittent operation. (*): Theoretical data. Efficiency values must be taken into account when calculating the power absorbed by the pump. H F OL 6 B 1 2 T 3 1 C 3 P 0 0 0 0 1 2 S 3 4 0 51 2 3 54 4 1 2 F 32 7 2 x 17.5 [2 x 1.07] 2 700 3 100 2 x 47 [2 x 12.42] 2 x 54 [2 x 14.27] 55 [74] 81 [109] 2 x 20 [2 x 1.22] 2 600 3 000 2 x 52 [2 x 13.74] 2 x 60 [2 x 15.85] 61 [82] 90 [121] 2 x 22 [2 x 1.34] 2 500 2 900 2 x 55 [2 x 14.53] 2 x 64 [2 x…
File type: application/pdf
Referenced at:
P L H Y D R A U LIC P U M P S T E C H N I C A L C A T A L O G 2 23/05/2017 PL Hydraulic Pumps POCLAIN HYDRAULICS CHARACTERISTICS Cont.: Continuous operation. Int.: Intermittent operation. (*): Theoretical data. Efficiency values must be taken into account when calculating the power absorbed by the pump. H F OL 6 B 1 2 T 3 1 C 3 P 0 0 0 0 1 2 S 3 4 0 51 2 3 54 4 1 2 F 32 7 2 x 17.5 [2 x 1.07] 2 700 3 100 2 x 47 [2 x 12.42] 2 x 54 [2 x 14.27] 55 [74] 81 [109] 2 x 20 [2 x 1.22] 2 600 3 000 2 x 52 [2 x 13.74] 2 x 60 [2 x 15.85] 61 [82] 90 [121] 2 x 22 [2 x 1.34] 2 500 2 900 2 x 55 [2 x 14.53] 2 x…
File type: application/pdf
Referenced at:
P M /P M E 50 V A R IA B LE D IS P LA C E M E N T P U M P C LO S E D LO O P C IR C U IT T E C H N I C A L C A T A L O G 2 02/11/2017 PM/PMe50 - Variable displacement pump POCLAIN HYDRAULICS OOVERVIEW PM/PMe50 is a variable displacement, axial piston pump, with swashplate system, for closed loop hydrostatic transmissions. It provides a continuously variable flow rate between zero and maximum in forward and reverse direction. Flow rate is proportional to rotation speed and swashplate angle. It can feature a charge pump to keep the circuit pressurised. This avoids risk of cavitations and ensures…
File type: application/pdf
Referenced at:
P M 30 V A R IA B LE D IS P LA C E M E N T P U M P C LO S E D LO O P C IR C U IT T E C H N I C A L C A T A L O G 2 05/10/2017 PM30 - Variable displacement pump POCLAIN HYDRAULICS OVERVIEW PM30 is a variable displacement, axial piston pump, with swashplate system, for closed loop hydrostatic transmissions. It provides a continuously variable flow rate between zero and maximum in forward and reverse direction. Flow rate is proportional to rotation speed and swashplate angle. It can feature a charge pump to keep the circuit pressurised. This avoids risk of cavitations and ensures a good…
File type: application/pdf
Referenced at:
P M 25 V A R IA B LE D IS P LA C E M E N T P U M P C LO S E D LO O P C IR C U IT T E C H N I C A L C A T A L O G 2 29/05/2017 PM25 - Variable displacement pump POCLAIN HYDRAULICS OOVERVIEW PM25 is a variable displacement, axial piston pump, with swashplate system, for closed loop hydrostatic transmissions. It provides a continuously variable flow rate between zero and maximum in forward and reverse direction. Flow rate is proportional to rotation speed and swashplate angle. It can feature a charge pump to keep the circuit pressurised. This avoids risk of cavitations and ensures a good…
File type: application/pdf
Referenced at:
P M 65 V A R IA B LE D IS P LA C E M E N T P U M P C LO S E D LO O P C IR C U IT T E C H N I C A L C A T A L O G 2 16/11/2016 PM65 - Variable displacement pump POCLAIN HYDRAULICS OVERVIEW PM65 is a variable displacement, axial piston pump, with swashplate system, for closed loop hydrostatic transmissions. It provides a continuously variable flow rate between zero and maximum in forward and reverse direction. Flow rate is proportional to rotation speed and swashplate angle. It can feature a charge pump to keep the circuit pressurised. This avoids risk of cavitations and ensures a good…
File type: application/pdf
Referenced at: